Fireberd 4000 Communications Analyzer

Product reference

6544

Product details

Specifications:

Operating Ranges:

Synchronous: 50 b/s to 15 Mb/s.
Asynchronous: 50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only).

Generator Timing:

Clock Sources: Fixed internal frequencies, data interface and external BNC.
Internal Clock Frequencies: 300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz +/- 5ppm.

Data Generator:

Fixed Patterns: Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length.
Pseudorandom Patterns: 63, 511, 2047, 215-1, 220-1, 223-1, QRSS.
Messages: Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length.
Asynchronous Setup: Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits.
Error Insertion: Single error or fixed 10-3 rate in generated data only.

Error Anaylsis Receiver:

Sync Loss Thresholds: User-Selectable 100/1000, 250/1000, and 20,000/100,000 errors/total bits.
Block Lengths: 102 to 106 bits, or pattern lengths.
Signal Analysis:
Frequency Measurement Range: 50 Hz to 16 MHz.
Accuracy: +/- 5ppm

Buying

£495.00
Price excludes VAT

1 in stock

Please contact us on +44 (0) 1263 710054
or sales@surplus-electronics.co.uk to purchase this item.